Reports, GasLift Design

<< Click to Display Table of Contents >>

Navigation:  Menus > Reports Menu  >

Reports, GasLift Design

Previous pageReturn to chapter overviewNext page

Reports Menu: GasLift Design Report

 

 

                                                                           Page  1

-----------------------------------------------------------------------------------

   Engineer :

    Dataset : 4225535696_20191026.snp

      Title : SAMPLE

-----------------------------------------------------------------------------------

Important Note: Review page 3 of this report for actual and potential problems.

                         Solution Rate: 2586 mscf/    Pvc Bottom Bellows:   615

GL Design Press:    786  Solution fbhp: 1002  psia    Operating Pressure:   862

Wellhead Pressure:  183  Flwg Wh Temp (Twh):   120    Casing DP:            142

SNAP IPR function        Top Valve Flwg Temp:  120    Orifice DP:           147

Static BHP(Pws):   6100  Static BH Temp:       160    KO Gas Gradient  : 0.0228

SNAP 2.699 11/11/2019    Tubing Size:        1.995    Operating Gas Grd: 0.0243

11/12/19  11:46:43       Design GL Rate:      1000    Watercut:          63.9 %

Model:  HagedornBrown    Unloading Gradient: 0.433    Liquid Yield:         229

Design QO:   214 stbf/d  Design QW:     378 stbf/d    Design QFmGas:2586 mscf/d

 

Rn Sta Depth Depth Valve Valve              Valve   Port   Valve   Valve      Flwg

Or  #   TVD    MD   OD    Type              Model   Size   Ap/Ab    Ppef       Tmp

12  1  1961  1961  1.0 Bellows           Camco_BK 0.2500  0.7000  0.1976       120

11  2  2941  2941  1.0 Bellows           Camco_BK 0.2500  0.7000  0.1976       120

10  3  3663  3663  1.0 Bellows           Camco_BK 0.2500  0.7000  0.1976       120

 9  4  4287  4287  1.0 Bellows           Camco_BK 0.2500  0.7000  0.1976       120

 8  5  4939  4939  1.0 Bellows           Camco_BK 0.2500  0.7000  0.1976       120

 7  6  5590  5591  1.0 Bellows           Camco_BK 0.2500  0.7000  0.1976       120

 6  7  6242  6245  1.0 Orifice           Camco_BK 0.3125  0.0000  0.0000       120

 5  8  6889  6902  1.0   Dummy                                                 120

 4  9  7529  7559  1.0   Dummy                                                 120

 3 10  8164  8214  1.0   Dummy                                                 120

 2 11  8816  8871  1.0   Dummy                                                 120

 1 12  9460  9523  1.0 Orifice           Camco_BK 0.2500  0.0000  0.0000       120

 

Rn Sta   Ppd     Pwf    Qg*  TGLR Qgi(req) Qgi(VPC) Qgi(ThH) Qgi(Wnk) Ptro60   Ptro

Or  #    Prs    psia mscf/d  scf/b   mscf    mscf     mscf     mscf   calc  Instld

12  1    305    1604   2499    200      0       0      920        0    798    1215

11  2    375    1575   2504    200      0       0      951        0    808    1205

10  3    429    1506   2516    200      0       0      978        0    805    1190

 9  4    479    1394   2534    200      0       0      994        0    799    1175

 8  5    532    1289   2550    200      0       0     1015        0    793    1165

 7  6    587    1180   2565    200      0       0     1036        0    788    1150

 6  7    643    1002   2586    200      0       1     1612     1973

 5  8    700   Dummy

 4  9    758   Dummy

 3 10    817   Dummy

 2 11    879   Dummy

 1 12    941    1002   2586   1000   1000     999      951     1067

 

Rn Sta  Pgd   GLD   GLD   GLD                      Pvc Ppd-Pmin

Or  #   Prs  Piod  Pvcd PpTran    Ct   Pio   Psc    DP     psia

12  1   831   831   752   353  0.886   788   715    20       48

11  2   853   822   762   461  0.886   754   695    20       87

10  3   870   810   759   498  0.886   727   675    20       68

 9  4   884   807   753   481  0.886   709   655    20        2

 8  5   899   801   748   476  0.886   689   635    20      -56

 7  6   914   796   743   470  0.886   669   615    20     -116

 6  7   929   667                                         -1230

 5  8   944 Dummy

 4  9   958 Dummy

 3 10   973 Dummy

 2 11   988 Dummy

 1 12  1002  1088                                           147

 

 

* Qliq values represent the minimum liquid rate that occurs during KO

 as gas begins to push around the next valve downhole.

 

                                                                     Page  2

-------------------------------------------------------------------------

-------------------------------------------------------------------------

WARNING   1:Tubing Prs is not 100 psi less than PTMin at Station 1  

PROBLEM:    You will not be able to transfer to the next lower station      

SOLUTION:   Either move the next lower valve up, or increase KO pressure    

 

WARNING   2:Tubing Prs is not 100 psi less than PTMin at Station 3  

PROBLEM:    You will not be able to transfer to the next lower station      

SOLUTION:   Either move the next lower valve up, or increase KO pressure